olztime.blogg.se

Deep sea configuration suite
Deep sea configuration suite









deep sea configuration suite deep sea configuration suite

It is suitable for use with either diesel or gas generator sets, and literally acts as the gen-set’s eyes and ears, providing constant feedback via illuminated LEDs, the back-lit LCD screen, remote PC, and (using an external modem) SMS text alerts. If this option is not selected the internal sounder will only stop once muted manually.The DSE7310 is an Auto Start Control Panel that monitors every important aspect of generator set performance, and displays that information along with any relevant warnings. It will also stop sounding if the mute button is pressed. The Auto Mute Timer Enable option will mean that the internal sounder is automatically muted after the period of time determined below. If the Sounder Enable option is not enabled the expansion module's internal sounder will not be active.īy selecting the Follow Main Unit any other connected DSE2548 modules and the host module will perform a lamp test/mute alarm if the mute alarm/lamp test button is pressed. If not selected, the expansion module will simply act as a remote display module. The Link Lost Alarm Action, is the same as listed above in the previous section with the same options Electrical Trip, Shutdown or Warning.Ĭontrol Buttons Enable, if this is enabled the expansion module will act as a complete mimic/control module of the primary control module. If the expansion is enabled the following options are available. The first option is simply to Enable or Disable the expansion. Once the Remote Display Module is added, the way this operates can now be modified in the Expansion section of the DSE Configuration Suite pictured below. Warning - A warning will be sounded but the Diesel Generator will not be shutdown. Shutdown - The load will be removed from the Diesel Generator and the Engine will stop immediately. This can be set to Electrical Trip, Shutdown or Warining.Įlectrical Trip - This will remove the load from the Diesel Generator and stop the Engine once the cooling period has passed. There is also an option for what action should be taken should the connection be lost between the two modules. The first option is to Enable or Disable the Remote Display. The DSE 25xx MK2 module can be added in the Remote Display section listed within the Communications section as shown below. These settings can only be changed on the Deep Sea Electronics Configuration Suite which can be downloaded from their website.

deep sea configuration suite

This can also be used to control your Diesel Generator remotely. A DSE 25xx MK2 Remote Display Module can be added to your Deep Sea Electronics module.











Deep sea configuration suite